Pillow block & flange units
Ready-to-bolt bearing units for conveyors, farm machines, fans, food and packaging lines. A cast-iron housing holds a UC insert bearing that locks on the shaft with two set screws and can be greased through the nipple. Filter by shaft size and compare bolt centres before you order.
UCP pillow block
H = shaft centre height, L = base length, J = bolt centres, A = base width, H2 = total height, N = bolt hole width.
| Designation | d | H | L | J | A | H2 | N | Bolt | Cr kN | Quote |
|---|---|---|---|---|---|---|---|---|---|---|
| UCP201Koyo UCP201 data | 12 | 30.2 | 127 | 95 | 38 | 60 | 13 | M10 | 12.8 | |
| UCP202Koyo UCP202 data | 15 | 30.2 | 127 | 95 | 38 | 60 | 13 | M10 | 12.8 | |
| UCP203Koyo UCP203 data | 17 | 30.2 | 127 | 95 | 38 | 60 | 13 | M10 | 12.8 | |
| UCP204Koyo UCP204 data | 20 | 33.3 | 127 | 95 | 38 | 65 | 13 | M10 | 12.8 | |
| UCP205Koyo UCP205 data | 25 | 36.5 | 140 | 105 | 38 | 70 | 13 | M10 | 14 | |
| UCP206Koyo UCP206 data | 30 | 42.9 | 165 | 121 | 48 | 84 | 17 | M14 | 19.5 | |
| UCP207Koyo UCP207 data | 35 | 47.6 | 167 | 127 | 48 | 95 | 17 | M14 | 25.7 | |
| UCP208Koyo UCP208 data | 40 | 49.2 | 184 | 137 | 54 | 98 | 17 | M14 | 29.1 | |
| UCP209Koyo UCP209 data | 45 | 54 | 190 | 146 | 54 | 106 | 17 | M14 | 34.1 | |
| UCP210Koyo UCP210 data | 50 | 57.2 | 206 | 159 | 60 | 113 | 20 | M16 | 35.1 | |
| UCP211Koyo UCP211 data | 55 | 63.5 | 219 | 171 | 60 | 125 | 20 | M16 | 43.4 | |
| UCP212Koyo UCP212 data | 60 | 69.8 | 241 | 184 | 70 | 138 | 20 | M16 | 52.4 | |
| UCP213Koyo UCP213 data | 65 | 76.2 | 265 | 203 | 70 | 150 | 25 | M20 | 57.2 | |
| UCP214Koyo UCP214 data | 70 | 79.4 | 266 | 210 | 72 | 157 | 25 | M20 | 62.2 | |
| UCP215Koyo UCP215 data | 75 | 82.6 | 275 | 217 | 74 | 162 | 25 | M20 | 67.4 | |
| UCP216Koyo UCP216 data | 80 | 88.9 | 292 | 232 | 78 | 174 | 25 | M20 | 72.7 | |
| UCP217Koyo UCP217 data | 85 | 95.2 | 310 | 247 | 83 | 185 | 25 | M20 | 84 | |
| UCP218Koyo UCP218 data | 90 | 101.6 | 327 | 262 | 88 | 198 | 27 | M22 | 96.1 |
UCF square flange
L = flange side, J = bolt centres, A = overall depth, N = bolt hole.
| Designation | d | L | J | A | N | Bolt | Cr kN | Quote |
|---|---|---|---|---|---|---|---|---|
| UCF204Koyo UCF204 data | 20 | 86 | 64 | 25.5 | 12 | M10 | 12.8 | |
| UCF205Koyo UCF205 data | 25 | 95 | 70 | 27 | 12 | M10 | 14 | |
| UCF206Koyo UCF206 data | 30 | 108 | 83 | 31 | 12 | M10 | 19.5 | |
| UCF207Koyo UCF207 data | 35 | 117 | 92 | 34 | 14 | M12 | 25.7 | |
| UCF208Koyo UCF208 data | 40 | 130 | 102 | 36 | 16 | M14 | 29.1 | |
| UCF209Koyo UCF209 data | 45 | 137 | 105 | 38 | 16 | M14 | 34.1 | |
| UCF210Koyo UCF210 data | 50 | 143 | 111 | 40 | 16 | M14 | 35.1 | |
| UCF211Koyo UCF211 data | 55 | 162 | 130 | 43 | 19 | M16 | 43.4 | |
| UCF212Koyo UCF212 data | 60 | 175 | 143 | 48 | 19 | M16 | 52.4 |
UCFL 2-bolt flange
Koyo letters: H = flange length, L = flange width, J = bolt centres, A = overall depth, N = bolt hole.
| Designation | d | H | L | J | A | N | Bolt | Cr kN | Quote |
|---|---|---|---|---|---|---|---|---|---|
| UCFL204Koyo UCFL204 data | 20 | 113 | 60 | 90 | 25.5 | 12 | M10 | 12.8 | |
| UCFL205Koyo UCFL205 data | 25 | 130 | 68 | 99 | 27 | 16 | M14 | 14 | |
| UCFL206Koyo UCFL206 data | 30 | 148 | 80 | 117 | 31 | 16 | M14 | 19.5 | |
| UCFL207Koyo UCFL207 data | 35 | 161 | 90 | 130 | 34 | 16 | M14 | 25.7 | |
| UCFL208Koyo UCFL208 data | 40 | 175 | 100 | 144 | 36 | 16 | M14 | 29.1 | |
| UCFL209Koyo UCFL209 data | 45 | 188 | 108 | 148 | 38 | 19 | M16 | 34.1 | |
| UCFL210Koyo UCFL210 data | 50 | 197 | 115 | 157 | 40 | 19 | M16 | 35.1 |
No size in this list matches. Send the number or size on WhatsApp and we'll find it.
Dimensions are standard and the same in every brand. Load ratings, speeds and mass are Koyo (JTEKT) catalogue figures, linked per row and checked 2026-11-27; other brands differ slightly. Prices on request: send brand and quantity for today's rate, GST invoice.
Three decisions, in this order.
Pillow or flange
UCP bolts to a flat base under the shaft. UCF (4 bolts) and UCFL (2 bolts) bolt to a wall or frame.
Shaft and bolt centres
Match the shaft diameter and the bolt centres J of the old unit, so it drops into the same holes. Centre height H matters for pillow blocks.
Replace only the insert?
If the housing is fine, change just the UC insert (UCP205 takes UC205). Cheaper and faster.
Bearing units bearings, answered.
What is the difference between UCP 205 and UCP 305?
Both fit a 25 mm shaft, but the 300 series is a heavier unit with a larger housing, centre height and bolt centres. They do not share mounting holes.
Can I replace only the bearing insert?
Yes. UCP 205 uses a UC 205 insert. Tilt it into the housing slots and turn it upright. We supply inserts and housings separately.
How do I measure a pillow block?
Shaft diameter, bolt hole centres (J) and the height from the base to the shaft centre (H). With these three we can match any brand.
Pillow block ka size kaise pata karein?
Shaft ka diameter, dono bolt ke beech ki doori (J) aur base se shaft ke centre tak ki unchai (H) naapiye, ya housing par likha number bhejiye.